Should I install a 240V outlet for a window AC in NB?

Question

Should I install a 240V outlet for a window AC in NB?

Answer from Electric IQ

For a window AC unit, a dedicated 240V outlet is almost certainly overkill — most window ACs run on standard 120V power and don't need a special circuit at all.

Window air conditioners are designed to plug into a regular 15A or 20A household outlet. The vast majority of units sold in Canada — even larger ones cooling 500–1,000 sq ft — operate on 120V. You'd only need a 240V circuit for very large commercial-grade window units (typically 18,000+ BTU), and even then, it's uncommon in residential settings. Before planning any electrical work, check the nameplate on your unit or the product specifications — it will clearly state the voltage and amperage requirements.

What you actually need to think about is whether your existing outlet can handle the load. A large window AC (10,000–15,000 BTU) can draw 10–15 amps on a 120V circuit. If that outlet is shared with other loads — a bedroom with lamps, a TV, a phone charger — you may trip breakers regularly. In that case, a dedicated 15A or 20A circuit for the AC makes sense, even if it's still 120V. This is a much simpler and less expensive project than running a 240V circuit.

From a TSANB and Canadian Electrical Code perspective, adding a new dedicated circuit does require a permit in New Brunswick, even if it's just a 120V outlet. A licensed electrician would pull the permit, run the circuit from your panel, install the appropriate outlet, and arrange the TSANB inspection. For a straightforward dedicated 120V circuit, you're typically looking at $300–$600 in the New Brunswick market. A 240V circuit would cost more — $400–$800+ depending on panel location and distance — so it's worth confirming you actually need it before going that route.

The one scenario where 240V makes sense is if you're planning ahead for a future mini-split heat pump. Mini-splits are extremely popular in NB given our heating costs, and they run on 240V. If you're thinking long-term, it might be worth having an electrician assess whether installing a 240V circuit now (and using a window AC temporarily) makes sense for your situation.

For safety, never use an extension cord with a window AC unit — it's a fire hazard and violates the Canadian Electrical Code. The unit should plug directly into a wall outlet rated for its amperage.

If you'd like help finding a licensed NB electrician to assess your panel and run the right circuit for your setup, New Brunswick Electrical can match you with a local electrician for free.

New Brunswick Electrical

Want this done at your place?

Tell us what you're planning and we'll get you a real estimate from a local New Brunswick electrician. We send it out to local licensed electricians for you. Free, no pressure.

Fields marked are required.

We won't call you. There's no phone box above because we don't ask for one — your estimate comes by email, on your time.

Request received We’ve sent your details to local New Brunswick electricians. They’ll contact you directly. A confirmation is on its way to your inbox.

Electric IQ — Built with local electrical expertise, NB Electrical Safety Code knowledge, and real trade experience. Answers are for informational purposes only.

Ready to Start Your Project?

Get a free, no-obligation estimate for your New Brunswick electrical project. We send your request to local licensed electricians — you choose who to hire.

Find an Electrician